Mitsubishi Galant 9G. Manual — part 38
SYMPTOM PROCEDURES
TSB Revision
SIMPLIFIED WIRING SYSTEM (SWS)
54B-148
STEP 3. Check the front door lock actuator (LH).
Remove the front door lock actuator (LH). The illustration
shows when the door lock actuator is viewed from inside the
door. Refer to GROUP 42
− Door Handle and Latch
Q: Does the front door lock actuator (LH) work normally?
YES : Go to Step 4.
NO : Replace the front door lock actuator (LH). Verify that
all the doors can be locked and unlocked normally.
STEP 4. Check ETACS-ECU connectors C-217 and C-219
for loose, corroded or damaged terminals, or terminals
pushed back in the connector.
Q: Are ETACS-ECU connectors C-217 and C-219 in good
condition?
YES : Go to Step 5.
NO : Repair or check the connector. Refer to GROUP 00E,
Harness Connector Inspection
. Verify that all
the doors can be locked and unlocked normally.
LEVER
POSITION
BATTERY
CONNECTION
LEVER
OPERATION
At the "LOCK"
position
• Connect terminal 6
to the negative
battery terminal
• Connect terminal 4
to the positive
battery terminal
The lever moves
from the "LOCK"
position to the
"UNLOCK"
position.
At the
"UNLOCK"
position
• Connect terminal 4
to the negative
battery terminal
• Connect terminal 6
to the positive
battery terminal
The lever moves
from the "UNLOCK"
position to the
"LOCK" position.
1 2 3
4 5 6
AC210903 AB
VIEW A
A
LOCK
UNLOCK
LEVER
AC305414
CONNECTORS: C-217, C-219
JUNCTION BLOCK
(REAR VIEW)
C-217
C-219
HARNESS SIDE
C-217
C-219
JUNCTION BLOCK SIDE
21
22
23
24
25
26
27
28
29
38 37 36 3534 33 32 31 30
39
40
41
42
43
44
AB
SYMPTOM PROCEDURES
TSB Revision
SIMPLIFIED WIRING SYSTEM (SWS)
54B-149
STEP 5. Check the wiring harness between ETACS-ECU
connector C-217 (terminal 22) and front door lock actuator
(LH) connector E-15 (terminal 4).
NOTE: Also check intermediate connector C-26 for loose, cor-
roded, or damaged terminals, or terminals pushed back in the
connector. If intermediate connector C-26 is damaged, repair or
replace the damaged component(s) as described in GROUP
00E, Harness Connector Inspection
.
Q: Is the wiring harness between ETACS-ECU connector
C-217 (terminal 22) and front door lock actuator (LH)
connector E-15 (terminal 4) in good condition?
YES : Go to Step 6.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair or replace the damaged component(s). Verify
that the central door locking system works normally.
AC305413AH
CONNECTOR: C-217
HARNESS SIDE
25
26
27
28
29
21
22
23
24
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
JUNCTION BLOCK
(REAR VIEW)
AC305262
E-15 (B)
HARNESS SIDE
CONNECTOR: E-15
AH
AC305231
CONNECTOR: C-26
AK
SYMPTOM PROCEDURES
TSB Revision
SIMPLIFIED WIRING SYSTEM (SWS)
54B-150
STEP 6. Check the wiring harness between ETACS-ECU
connector C-219 (terminal 12) and front door lock actuator
(LH) connector E-15 (terminal 6).
NOTE: Also check intermediate connector C-26 and junction
block connector C-211 for loose, corroded, or damaged termi-
nals, or terminals pushed back in the connector. If intermediate
connector C-26 or junction block connector C-211 is damaged,
repair or replace the damaged component(s) as described in
GROUP 00E, Harness Connector Inspection
Q: Is the wiring harness between ETACS-ECU connector
C-219 (terminal 12) and front door lock actuator (LH)
connector E-15 (terminal 6) in good condition?
YES : Replace the ETACS-ECU. Verify that all the doors
can be locked and unlocked normally.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair or replace the damaged component(s). Verify
that the central door locking system works normally.
AC305413 AG
CONNECTOR: C-219
JUNCTION BLOCK SIDE
JUNCTION BLOCK
(REAR VIEW)
AC305262
E-15 (B)
HARNESS SIDE
CONNECTOR: E-15
AH
AC305231
CONNECTOR: C-26
AK
AC305415AH
CONNECTOR: C-211
C-211
HARNESS SIDE
JUNCTION BLOCK
(FRONT VIEW)
SYMPTOM PROCEDURES
TSB Revision
SIMPLIFIED WIRING SYSTEM (SWS)
54B-151
STEP 7. Check front door lock actuator (RH) connector
E-05 for loose, corroded or damaged terminals, or
terminals pushed back in the connector.
Q: Is front door lock actuator (RH) connector E-05 in good
condition?
YES : Go to Step 8.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
. Verify that all the doors can be locked and
unlocked normally.
STEP 8. Check the front door lock actuator (RH).
Remove the front door lock actuator (RH). The illustration
shows when the door lock actuator is viewed from inside the
door. Refer to GROUP 42
− Door Handle and Latch
Q: Is the front door lock actuator (RH) normal?
YES : Go to Step 9.
NO : Replace the front door lock actuator (RH). Verify that
all the doors can be locked and unlocked normally.
AC305333
AH
CONNECTOR: E-05
E-05 (B)
HARNESS SIDE
LEVER
POSITION
BATTERY
CONNECTION
LEVER
OPERATION
At the "LOCK"
position
• Connect terminal 4
to the negative
battery terminal
• Connect terminal 6
to the positive
battery terminal
The lever moves
from the "LOCK"
position to the
"UNLOCK"
position.
At the
"UNLOCK"
position
• Connect terminal 6
to the negative
battery terminal
• Connect terminal 4
to the positive
battery terminal
The lever moves
from the
"UNLOCK" position
to the "LOCK"
position.
AC210905
1 2 3
4 5 6
VIEW A
B
LOCK
LEVER
UNLOCK
AB