Mitsubishi L200. Manual — part 637
TROUBLESHOOTING
SUPPLEMENTAL RESTRAINT SYSTEM (SRS)
52B-219
STEP 4. Check SRS-ECU connector C-154.
AC801404
AJ
Connector: C-154
C-154 (Y)
Harness side
connector
(rear view)
Q: Is the connector correctly engaged?
YES :
Go to Step 5.
NO :
Engage the connector correctly. Then go to
Step 7.
STEP 5. Check the harness for short circuit
between the combination meter connector C-113
(terminal No.18) and SRS-ECU connector C-154
(terminal No.39).
AC903856BM
Connector: C-113 <LHD>
Harness side
connector
(rear view)
AC903868
CC
Connector: C-113 <RHD>
Harness side
connector
(rear view)
AC801404
AJ
Connector: C-154
C-154 (Y)
Harness side
connector
(rear view)
Q: Is the check result normal?
YES :
Go to Step 6.
NO :
Repair the harness wires between the
combination meter connector C-113
(terminal No.18) and SRS-ECU connector
C-154 (terminal No.39). Then go to Step 7.
TROUBLESHOOTING
SUPPLEMENTAL RESTRAINT SYSTEM (SRS)
52B-220
STEP 6. Check the SRS warning lamp.
(1) Disconnect the negative battery terminal.
AC801404
AJ
Connector: C-154
C-154 (Y)
Harness side
connector
(rear view)
(2) Disconnected the SRS-ECU connector C-154.
(3) Connect the negative battery terminal.
(4) Turn the ignition switch to the "ON" position.
Q: Does the SRS warning lamp illuminate?
YES :
Go to Step 7.
NO :
Replace the combination meter (Refer to
GROUP 54A, Combination Meter Assembly
). Go to Step 7.
STEP 7. Check whether the diagnosis code is
reset.
Check again if the diagnosis code is set.
(1) Erase the diagnosis code.
(2) Ignition: "LOCK" (OFF) position to "ON"
(3) On completion, check that the diagnosis code is
not reset.
Q: Is the diagnosis code set?
YES :
).
NO :
An intermittent malfunction is suspected
(Refer to GROUP 00, How to Cope with
Intermittent Malfunction ).
TROUBLESHOOTING
SUPPLEMENTAL RESTRAINT SYSTEM (SRS)
52B-221
Code No.B1551: SRS warning lamp circuit malfunction (Lamp does not Switch Off).
AC801181
Wire colour code
B : Black LG : Light green G : Green L : Blue W : White Y : Yellow SB : Sky blue
BR : Brown O : Orange GR : Grey R : Red P : Pink V : Violet PU : Purple
SRS Warning Lamp Drive Circuit
IGNITION
SWITCH (IG1)
COMBINATION
METER
SRS-ECU
AD
OPERATION
• Power for the SRS warning lamp is supplied from
the ignition switch (IG1) circuit.
• The SRS warning lamp illuminates when the igni-
tion switch is turned to the "ON" position and
goes out after approximately 7 seconds if there is
not a malfunction in the SRS system.
DIAGNOSIS CODE SET CONDITIONS
• This diagnosis code will be set if an open circuit
has occurred in the wiring harness between the
combination meter and the SRS-ECU.
TROUBLESHOOTING HINTS
• Damaged wiring harnesses of connectors
• Malfunction of the SRS-ECU
• Malfunction of the combination meter
TROUBLESHOOTING
SUPPLEMENTAL RESTRAINT SYSTEM (SRS)
52B-222
DIAGNOSIS PROCEDURE
STEP 1. M.U.T.-III diagnosis code.
Q: Is the diagnosis code set?
YES :
Perform the troubleshooting to the set
diagnosis code. (Refer to
).
NO :
Go to Step 2.
STEP 2. Check the harness between SRS-ECU
connector C-154 (terminal No.39) and the
combination meter connector C-113 (terminal
No.18).
AC903856BM
Connector: C-113 <LHD>
Harness side
connector
(rear view)
AC903868
CC
Connector: C-113 <RHD>
Harness side
connector
(rear view)
AC801404
AJ
Connector: C-154
C-154 (Y)
Harness side
connector
(rear view)
• Check the SRS warning lamp output lines for
open circuit.
Q: Is the check result normal?
YES :
Go to Step 3.
NO :
Repair the harness wires. Then go to Step
4.
STEP 3. Check the SRS warning lamp.
(1) Disconnect the negative battery terminal.
AC801404
AJ
Connector: C-154
C-154 (Y)
Harness side
connector
(rear view)
(2) Disconnected the SRS-ECU connector C-154.
(3) Connect the negative battery terminal.
(4) Turn the ignition switch to the "ON" position.
CAUTION
Do not insert a test probe into the terminal from
its front side directly, as the connector contact
pressure may be weakened.
(5) Check that SRS warning lamp turn "ON" when
SRS-ECU connector C-154 is disconnected.
Check that the same warning lamp turn "OFF"
when the terminal No.39 of the above connector
is earthed.
Q: Is the check result normal?
YES :
Go to Step 4
NO :
Replace the combination meter (Refer to
GROUP 54A, Combination Meter Assembly
).
STEP 4. Check whether the diagnosis code is
reset.
Check again if the diagnosis code is set.
(1) Erase the diagnosis code.
(2) Ignition: "LOCK" (OFF) position to "ON"
(3) On completion, check that the diagnosis code is
not reset.
Q: Is the diagnosis code set?
YES :
).
NO :
An intermittent malfunction is suspected
(Refer to GROUP 00, How to Cope with
Intermittent Malfunction ).
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.