Dodge Dakota (ND). Manual — part 344
*RIGHT DOORS FAIL TO LOCK AND UNLOCK – QUAD CAB (CONTINUED)
3.
(P392) DOOR LOCK DRIVER RIGHT DOORS WIRE OPEN
Disconnect the Right Front Door Latch connector.
Measure the resistance of the (P392) Door Lock Driver Right Doors
circuit between the Instrument Cluster C1 connector and the Right
Front Door Latch connector.
Is the resistance below 5.0 ohms?
Yes
>> Go To 4
No
>> Repair the (P392) Door Lock Driver Right Doors wire for
an open.
Perform BODY VERIFICATION TEST - VER 1. (Refer to
BODY VERIFICATION TEST - VER 1.)
4.
(G778) DOOR UNLOCK DRIVER RIGHT DOORS WIRE OPEN
Measure the resistance of the (G778) Door Unlock Driver Right Doors
circuit between the Instrument Cluster C1 connector and the Right
Front Door Latch connector.
Is the resistance below 5.0 ohms?
Yes
>> Replace the Door Latch.
Perform BODY VERIFICATION TEST - VER 1. (Refer to
BODY VERIFICATION TEST - VER 1.)
No
>> Repair the (G778) Door Unlock Driver Right Doors wire for
an open.
Perform BODY VERIFICATION TEST - VER 1. (Refer to
BODY VERIFICATION TEST - VER 1.)
8N - 52
POWER LOCKS - ELECTRICAL DIAGNOSTICS
ND
*RIGHT DOORS UNLOCK ONLY – QUAD CAB
ND
POWER LOCKS - ELECTRICAL DIAGNOSTICS
8N - 53
*RIGHT DOORS UNLOCK ONLY – QUAD CAB (CONTINUED)
For the Power Door Lock circuit diagram (Refer to 8 - ELECTRICAL/POWER LOCKS - SCHEMATICS AND DIA-
GRAMS).
For a complete wiring diagram Refer to Section 8W.
Possible Causes
(P392) DOOR LOCK DRIVER RIGHT DOORS CIRCUIT SHORT TO GROUND
CLUSTER
Diagnostic Test
1.
CHECK FOR ACTIVE DTC B182D-ALL DOOR LOCK OUTPUT CIRCUIT SHORTED TO GROUND
Turn the ignition on.
With the scan tool, read active DTC’s.
Does the scan tool display any Door Lock related DTC’s?
No
>> Go To 2
Yes
>> Refer to the symptom list for problems related to Power
Door Locks. Diagnose and repair the DTC’s
2.
CHECK (P392) DOOR LOCK DRIVER RIGHT DOORS FOR SHORT TO GROUND
Turn the ignition off.
Disconnect the Cluster C1 connector.
Measure the resistance between ground and the (P392) Door Lock
Driver Right Doors circuit.
Is the resistance below 1000.0 ohms?
No
>> Replace the Cluster in accordance with service informa-
tion.
Perform BODY VERIFICATION TEST - VER 1. (Refer to 8
- ELECTRICAL/POWER LOCKS - DIAGNOSIS AND
TESTING)
Yes
>> Repair the (P392) Door Lock Driver Right Doors circuit for
a short to ground.
Perform BODY VERIFICATION TEST - VER 1. (Refer to 8 - ELECTRICAL/POWER LOCKS - DIAGNO-
SIS AND TESTING)
8N - 54
POWER LOCKS - ELECTRICAL DIAGNOSTICS
ND
*RIGHT DOORS LOCK ONLY – QUAD CAB
ND
POWER LOCKS - ELECTRICAL DIAGNOSTICS
8N - 55