ASSEMBLY
AT-393
D
E
F
G
H
I
J
K
L
M
A
B
AT
CAUTION:
●
Hang down terminal cord assembly and revolution sen-
sor harness toward outside so as not to disturb installa-
tion of control valve assembly.
●
Make sure that turbine sensor securely installs turbine
sensor hole.
●
Assemble it so that manual valve cutout is engaged with
manual plate projection.
b.
Install bolts A, B and C in control valve assembly.
c.
Tighten bolt 1, 2 and 3 temporarily to prevent dislocation. After
that tighten them in order (1
→
2
→
3), and then tighten other
bolts.
12. Install terminal cord assembly connectors in bracket.
13. Connect terminal cord assembly connectors.
SCIA2812E
Bolt symbol
Length mm (in)
Number of bolts
A
42 (1.65)
5
B
55 (2.17)
6
C
40 (1.57)
1
: 7.9 N·m (0.81 kg-m, 70 in-lb)
SCIA2312E
SCIA3170E
SCIA2584E
SCIA2309E
AT-394
ASSEMBLY
14. Connect A/T fluid temperature sensor 2 connector.
15. Connect revolution sensor connector.
16. Securely fasten terminal harness with terminal clips.
17. Install magnets in oil pan.
18. Install oil pan in transmission case.
a.
Install oil pan gasket in transmission case.
CAUTION:
●
Do not reuse oil pan gasket.
●
Install it in the direction to align hole positions.
●
Completely remove all moisture, oil and old gasket, etc. from oil pan gasket mounting surface.
SCIA5129E
SCIA2313E
SCIA2314E
SCIA5200E
ASSEMBLY
AT-395
D
E
F
G
H
I
J
K
L
M
A
B
AT
b.
Install oil pan in transmission case.
CAUTION:
●
Install it so that drain plug comes to the position as
shown in the figure.
●
Be careful not to pinch harnesses.
●
Completely remove all moisture, oil and old gasket, etc.
from oil pan gasket mounting surface.
c.
Tighten oil pan mounting bolts to the specified torque in numeri-
cal order shown in the figure after temporarily tightening them.
CAUTION:
Do not reuse oil pan mounting bolts.
19. Install drain plug in oil pan.
CAUTION:
Do not reuse drain plug gasket.
20. Install torque converter.
a.
Pour ATF into torque converter.
●
Approximately 2 liter (2-1/8 US qt, 1-3/4 Imp qt) of fluid is
required for a new torque converter.
●
When reusing old torque converter, add the same amount
of fluid as was drained.
b.
Install torque converter while aligning notches of torque con-
verter with notches of oil pump.
SCIA2308E
: 7.9 N·m (0.81 kg-m, 70 in-lb)
: 34 N·m (3.5 kg-m, 25 ft-lb)
SCIA4113E
SAT428DA
SCIA2297E
AT-396
ASSEMBLY
c.
Measure distance “A” to check that torque converter is in proper
position.
Distance “A”
: 22.0 mm (0.87 in) or more
SCIA5694E