Infiniti FX35, FX50 (S51). Manual — part 1517

AUTO OPERATION DOES NOT OPERATE BUT MANUAL OPERATE NORMAL-

LY

PWC-129

< SYMPTOM DIAGNOSIS >

[FRONT & REAR WINDOW ANTI-PINCH]

C

D

E

F

G

H

I

J

L

M

A

B

PWC

N

O

P

REAR LH : Diagnosis Procedure

INFOID:0000000005248237

1.

PERFORM INITIALIZATION PROCEDURE

Initialization procedure is performed and operation is confirmed.
Refer to

PWC-8, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Special

Repair Requirement"

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> GO TO 2.

2.

CHECK ENCODER (REAR LH) CIRCUIT

Check encoder (rear LH) circuit.
Refer to

PWC-33, "REAR LH : Component Function Check"

.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace the malfunctioning parts.

3.

CONFIRM THE OPERATION

Confirm the operation again.

Is the result normal?

YES

>> Check intermittent incident. Refer to

GI-36, "Intermittent Incident"

.

NO

>> GO TO 1.

REAR RH

REAR RH : Diagnosis Procedure

INFOID:0000000005248238

1.

PERFORM INITIALIZATION PROCEDURE

Initialization procedure is performed and operation is confirmed.
Refer to

PWC-8, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Special

Repair Requirement"

.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> GO TO 2.

2.

CHECK ENCODER (REAR RH) CIRCUIT

Check encoder (rear RH) circuit.
Refer to

PWC-35, "REAR RH : Component Function Check"

.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace the malfunctioning parts.

3.

CONFIRM THE OPERATION

Confirm the operation again.

Is the result normal?

YES

>> Check intermittent incident. Refer to

GI-36, "Intermittent Incident"

.

NO

>> GO TO 1.

PWC-130

< SYMPTOM DIAGNOSIS >

[FRONT & REAR WINDOW ANTI-PINCH]

POWER WINDOW RETAINED POWER OPERATION DOES NOT OPERATE

PROPERLY

POWER WINDOW RETAINED POWER OPERATION DOES NOT OPER-
ATE PROPERLY

Diagnosis Procedure

INFOID:0000000005248239

1.

CHECK DOOR SWITCH

Check door switch.
Refer to

PWC-27, "Component Function Check"

.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace the malfunctioning parts.

2.

CONFIRM THE OPERATION

Confirm the operation again.

Is the result normal?

YES

>> Check intermittent incident. Refer to

GI-36, "Intermittent Incident"

.

NO

>> GO TO 1.

POWER WINDOW DOWN FUNCTION DOES NOT OPERATE WITH KEY CYLIN-

DER OPERATION

PWC-131

< SYMPTOM DIAGNOSIS >

[FRONT & REAR WINDOW ANTI-PINCH]

C

D

E

F

G

H

I

J

L

M

A

B

PWC

N

O

P

POWER WINDOW DOWN FUNCTION DOES NOT OPERATE WITH KEY
CYLINDER OPERATION

Diagnosis Procedure

INFOID:0000000005248240

1.

PERFORM INITIALIZATION PROCEDURE

Initialization procedure is performed and operation is confirmed.
Refer to

PWC-8, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Special

Repair Requirement"

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> GO TO 2.

2.

CHECK DRIVER SIDE DOOR LOCK ASSEMBLY (KEY CYLINDER SWITCH)

Check driver side door lock assembly (key cylinder switch).
Refer to

PWC-38, "Component Function Check"

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace the malfunctioning parts.

3.

CONFIRM THE OPERATION

Confirm the operation again.

Is the result normal?

YES

>> Check intermittent incident. Refer to

GI-36, "Intermittent Incident"

NO

>> GO TO 1.

PWC-132

< SYMPTOM DIAGNOSIS >

[FRONT & REAR WINDOW ANTI-PINCH]

POWER WINDOW DOWN FUNCTION DOES NOT WORK WHEN OPERATING

WITH INTELLIGENT KEY

POWER WINDOW DOWN FUNCTION DOES NOT WORK WHEN OPERAT-
ING WITH INTELLIGENT KEY

Description

INFOID:0000000005248241

NOTE:
Before performing the diagnosis in the following procedure, check “ Work Flow”. Refer to

DLK-8, "Work Flow"

.

Diagnosis Procedure

INFOID:0000000005248242

1.

CHECK REMOTE KEYLESS ENTRY FUNCTION

Check remote keyless entry function.
Does door lock/unlock with Intelligent key button?

YES

>> GO TO 2.

NO

>> Go to

DLK-200, "Description"

.

2.

CHECK POWER WINDOW OPERATION

Check power window operation.

Does power window up/down with power window main switch?

YES

>> GO TO 3.

NO

>> Go to

PWC-16, "POWER WINDOW MAIN SWITCH : Diagnosis Procedure"

.

3.

CHECK “PW DOWN SET” SETTING IN “WORK SUPPORT”

Check “PW DOWN SET” setting in “WORK SUPPORT”.
Refer to

DLK-54, "INTELLIGENT KEY : CONSULT-III Function (BCM - INTELLIGENT KEY)"

.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Set “PW DOWN SET” setting in “WORK SUPPORT”.

4.

CONFIRM THE OPERATION

Confirm the operation again.

Is the result normal?

YES

>> Check intermittent incident. Refer to

GI-36, "Intermittent Incident"

.

NO

>> GO TO 1.