Volkswagen Golf / Golf GTI / Jetta. Manual — part 1035
01-52
- Interrupt "Reading distance impulse number"
with "C" button.
Adaptation
Enter channel number XX
Indicated on display:
- Press "C" button.
Rapid data transfer
HELP
Select function XX
Indicated on display:
- Press buttons -0- and -6- to select "End Output"
function 06.
Rapid data transfer
Q
06 - End Output
Indicated on display:
- Press -Q- button to confirm input.
Rapid data transfer
Help
Enter address word XX
Indicated on display:
The tester is now in basic function again.
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
01-53
Fuel gauge, checking
If the fuel gauge displays the contents of the fuel
tanks as being too high or too low, the fuel gauge
needle position can be corrected (adapted).
First perform the following procedures:
- Perform Output Diagnostic Test Mode (DTM) for
instrument cluster
Page 01-20
.
If Output Diagnostic Test Mode (DTM) does not
recognize a malfunction, check function of
sender for fuel gauge -G-:
- Check resistance value of sender for fuel gauge
in read measuring value block, display group
002
Page 01-33
.
If Read Measuring Value Block does not indicate
a short or open circuit in the wiring or the fuel
gauge sender, continue with adaptation
Page
01-54
.
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
01-54
Fuel gauge, adaptation
Special tools, testers, and
auxiliary items required
WARNING!
Fuel extraction unit VAG 1433 A
(or equivalent, approved fuel
cart)
- Switch off ignition.
- Drain fuel tank completely using
fuel extraction unit, then fill with 7
liters (1.85 gallons) of fuel.
Fire hazard. DO NOT smoke or
work near heaters or have
anything in the area that can
ignite fuel.
Always drain fuel from fuel tank
using an approved fuel cart.
Wear fuel-resistant gloves
whenever working with open
parts of the fuel system.
- Connect scan tool VAG 1551,
select operating mode 1 "Rapid
data transfer", switch on ignition
and enter address word 17
"instrument cluster".
- Press -Q- button to confirm input.
- Press
button until "Select
function"appears in display.
Rapid data transfer
HELP
Select function XX
Indicated on display:
- Press buttons -1- and -0- to select
"Adaptation" function 10.
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
01-55
Rapid data transfer
Q
10 - Adaptation
Indicated on display:
- Press -Q- button to confirm input.
Adaptation
Enter channel number XX
Indicated on display:
- Press buttons -3- and -0- to select
adaptation "channel 30".
- Press -Q- button to confirm input.
Channel 30 Adaptation 128
- 1 3-
Indicated on display:
Notes:
At least 60 seconds must pass
between adding fuel and reading
fuel gauge.
Before this time passes, the fuel
gauge reading is unreliable due
to the movement of the added
fuel.
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.