Volkswagen Golf / Golf GTI / Jetta. Manual — part 175
01-242
Display group 57 - Speed control - Idling stabilization
Engine running at idle
Read measured value
block 57
Indicated on
display
xxxx
rpm
xxxx
rpm
Text
---
1
2
3
4
Display zones
Specification
Evaluation
No display
---
---
Air conditioning compressor
operating mode
(Compr. ON / Compr. OFF)
Compr. ON or
Compr. OFF
---
Engine speed (specified idle
speed)
700 rpm
---
Engine speed (actual idle speed)
640...720 rpm
Page 01-
188
Notes on display zones 1 and 2:
The rpm in display zone 1 (measured revolutions) is the actual engine speed.
The rpm in display zone 2 (specified rpm) is theoretical engine speed calculated by
the Motronic Engine Control Module (ECM) -J220-. at idle, the Motronic Engine
Control Module (ECM) -J220- always tries to adapt the actual engine speed to the
specified engine speed.
Measured value (data) blocks
01-243
Display group 60 - Speed control - Electronic power control (EPC) system
adaption
1)
Control module in function "04-Basic setting"
Ignition on, engine not running
System in basic
setting 60
Indicated on display
xxx % xxx % x Text
1
2
3
4
Display zones
Specification Evaluation
Adaption status
(ADP. runs / ADP. OK. /
ADP ERROR)
ADP. OK.
---
Learning step counter
0...8
---
Throttle valve angle
Angle sensor -2- for throttle drive -
G188-
100...0 %
---
Throttle valve angle
Angle sensor -1- for throttle drive -G187-
0...100 %
---
1)
Erase learned values and adapt (match) Motronic Engine Control Module (ECM) -
J220- to Throttle Valve Control Module
Page 24-182
.
Measured value (data) blocks
01-244
Note on display group 60:
Adapting the Throttle Valve Control Module -J338- is performed with ignition
switched on.
Motronic Engine Control Module (ECM) -J220- is adapted to throttle valve control
module when selecting display group 60 under function "04-Basic setting". This
adaption must always be carried out when another Throttle Valve Control Module -
J338- (or another complete engine) or another Motronic Engine Control Module
(ECM) -J220- is installed.
The specifications indicated in display zones 1 and 2 do not fully reach the max. min.
figures.
The throttle valve angle sensors are opposed. The values from both angle sensors
must always add up to approx. 100 %.
The counter counts from 0 to 8 in display zone 3 during the adaption.
Measured value (data) blocks
01-245
Display group 61 - Speed control - Electronic Power Control system
While driving
Read measured value
block 61
Indicated on
display
xxxx
rpm
xx.xxx
V
xxx.x
%
xxxxx
1
2
3
4
Display zones
Specification
Evaluation
Operating
condition
xxxxx
Page 01-
240
Throttle valve angle
Angle sensor -1- for throttle
drive -G187-
0.0...100.0 %
---
Voltage supply for Motronic Engine
Control Module (ECM) -J220-
11.500...15.000
V
Page 01-
194
Engine speed
640...6500 rpm
---
Note on display zone 3:
The specifications do not fully reach the max./min. figures.
Measured value (data) blocks
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст