Volkswagen Golf / Golf GTI / Jetta. Manual — part 1056

01-132

Note:

Replace fuel gauge sender only if fuel gauge
cannot be matched correctly.

- Press buttons -0- and -6- to select "End Output"

function 06.

Rapid data transfer

Q

06 End Output

Indicated on display:

- Press -Q- button to confirm input.

Rapid data transfer

Help

Enter address word XX

Indicated on display:

The tester is now in basic function again.

Instrument cluster m.y. 2000 through m.y. 2001, On Board Diagnostic (OBD)

13/2/2005

01-133

Multi-function Indicator (MFI) fuel
consumption indicator, adaptation

Notes:

Consumption indicator can only be adapted

once between 85% and 115%.

Value must be entered in steps of 5%.

- Connect scan tool VAG 1551, select operating

mode 1 "Rapid data transfer", switch on ignition
and enter address word 17 "instrument cluster".

- Press -Q- button to confirm input.

- Press

button until "Select function"appears in

display.

Rapid data transfer

HELP

Select function XX

Indicated on display:

- Press buttons -1- and -0- to select "Adaptation"

function 10.

Rapid data transfer

Q

10 - Adaptation

Indicated on display:

- Press -Q- button to confirm input.

Adaptation

Enter channel number XX

Indicated on display:

- Press buttons -0- and -3- to select adaptation

"channel 03".

- Press -Q- button to confirm input.

Instrument cluster m.y. 2000 through m.y. 2001, On Board Diagnostic (OBD)

13/2/2005

01-134

Channel 03 Adaptation 100

- 1 3-

Indicated on display:

Note:

Correction of fuel consumption
display is only possible via direct
input.

- Press

button to continue.

Channel 03 Adaptation 100

Enter adaptation value XXXXX

Indicated on display:

Example:

Desired input value: 90% = button
pad entry: 00090

- Input desired correction value

using scan tool button pad, filling
initial positions with "0".

Channel 03 Adaptation 100

Q

Enter adaptation value 00090

Indicated on display:

- Press -Q- button to confirm input.

Channel 03 Adaptation 90

Q

- 1 3-

Indicated on display:

- Press -Q- button to confirm input.

Channel 03 Adaptation 90

Q

Store changed value?

Indicated on display:

- Press -Q- button to confirm input.

Instrument cluster m.y. 2000 through m.y. 2001, On Board Diagnostic (OBD)

13/2/2005

01-135

Channel 03 Adaptation 90

Changed value is stored

Indicated on display:

- End consumption indicator

adaptation with

button.

Rapid data transfer

HELP

Select function XX

Indicated on display:

Note:

A false entry switches the tester to
"Select function" mode.

Function is unknown or

cannot be carried out at the moment

If the following display appears:

- Press

button.

- Select function "10 - Adaptation"

and adaptation channel 03 again.

- Carry out corrections to

consumption indicator and
confirm with Q button.

Instrument cluster m.y. 2000 through m.y. 2001, On Board Diagnostic (OBD)

13/2/2005

Была ли эта страница вам полезна?
Да!Нет
3 посетителя считают эту страницу полезной.
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности