Volkswagen Golf / Golf GTI / Jetta. Manual — part 1056
01-132
Note:
Replace fuel gauge sender only if fuel gauge
cannot be matched correctly.
- Press buttons -0- and -6- to select "End Output"
function 06.
Rapid data transfer
Q
06 End Output
Indicated on display:
- Press -Q- button to confirm input.
Rapid data transfer
Help
Enter address word XX
Indicated on display:
The tester is now in basic function again.
Instrument cluster m.y. 2000 through m.y. 2001, On Board Diagnostic (OBD)
13/2/2005
01-133
Multi-function Indicator (MFI) fuel
consumption indicator, adaptation
Notes:
Consumption indicator can only be adapted
once between 85% and 115%.
Value must be entered in steps of 5%.
- Connect scan tool VAG 1551, select operating
mode 1 "Rapid data transfer", switch on ignition
and enter address word 17 "instrument cluster".
- Press -Q- button to confirm input.
- Press
button until "Select function"appears in
display.
Rapid data transfer
HELP
Select function XX
Indicated on display:
- Press buttons -1- and -0- to select "Adaptation"
function 10.
Rapid data transfer
Q
10 - Adaptation
Indicated on display:
- Press -Q- button to confirm input.
Adaptation
Enter channel number XX
Indicated on display:
- Press buttons -0- and -3- to select adaptation
"channel 03".
- Press -Q- button to confirm input.
Instrument cluster m.y. 2000 through m.y. 2001, On Board Diagnostic (OBD)
13/2/2005
01-134
Channel 03 Adaptation 100
- 1 3-
Indicated on display:
Note:
Correction of fuel consumption
display is only possible via direct
input.
- Press
button to continue.
Channel 03 Adaptation 100
Enter adaptation value XXXXX
Indicated on display:
Example:
Desired input value: 90% = button
pad entry: 00090
- Input desired correction value
using scan tool button pad, filling
initial positions with "0".
Channel 03 Adaptation 100
Q
Enter adaptation value 00090
Indicated on display:
- Press -Q- button to confirm input.
Channel 03 Adaptation 90
Q
- 1 3-
Indicated on display:
- Press -Q- button to confirm input.
Channel 03 Adaptation 90
Q
Store changed value?
Indicated on display:
- Press -Q- button to confirm input.
Instrument cluster m.y. 2000 through m.y. 2001, On Board Diagnostic (OBD)
13/2/2005
01-135
Channel 03 Adaptation 90
Changed value is stored
Indicated on display:
- End consumption indicator
adaptation with
button.
Rapid data transfer
HELP
Select function XX
Indicated on display:
Note:
A false entry switches the tester to
"Select function" mode.
Function is unknown or
cannot be carried out at the moment
If the following display appears:
- Press
button.
- Select function "10 - Adaptation"
and adaptation channel 03 again.
- Carry out corrections to
consumption indicator and
confirm with Q button.
Instrument cluster m.y. 2000 through m.y. 2001, On Board Diagnostic (OBD)