Volkswagen Golf / Golf GTI / Jetta. Manual — part 160
01-182
Measured value (data) blocks
Safety precautions
Observe following if test and measuring
instruments are required during a road test:
Test and measuring instruments must be
secured to rear seat and operated by a 2nd
person from this location.
If test and measuring instruments are operated
from front passenger's seat and the vehicle is
involved in an accident, there is a possibility that
the person sitting in this seat may receive
serious injuries when the airbag is triggered.
Measured value (data) blocks
01-183
Read measured value (data)
block
The measured values in the
functions read measured value block
and basic setting are described
during the individual component test.
This table serves only as an
overview.
Special tools and equipment
Note:
All functions which could previously
be performed with VAG 1551/1552
can also be performed with the
vehicle diagnostic, testing and
information system VAS 5051.
Test requirements
VAG 1551 scan tool (or VAG
1552 vehicle system tester) with
VAG 1551/3 adapter cable
The fuses must be OK.
Measured value (data) blocks
01-184
The main fuses must be OK.
The battery voltage must be at
least 11.5 V.
Ground (GND) connection
between engine and body must
be OK.
All electrical devices, e.g. lights
and rear window defroster must
be switched off.
If the vehicle is equipped with air
conditioning, this must be
switched off.
Selector lever must be in
position "P" or "N" on vehicles
with an automatic transmission.
Coolant temperature must be at
least 85 C,
display group 1,
display zone 2.
Three Way Catalytic Converter
(TWC) temperature must be at
least 380 C,
display group
46, display zone 2.
No Diagnostic Trouble Codes
(DTCs) must be stored in DTC
memory
Page 01-23
, DTC
memory, checking and erasing.
Measured value (data) blocks
01-185
Work sequence
- Connect VAG 1551 scan tool ((VAG 1552) and
select Engine Control Module (ECM) with the
"Address word" 01. When doing this the engine
must be running at idle: (Connecting scan tool
and selecting Engine Control Module (ECM)
Page 01-12
).
Rapid data transfer
HELP
Select function XX
Indicated on display:
- Press buttons -0- and -8- for function "Read
measured value (data) block" and confirm entry
with -Q- button.
Read measured value (data) block
Input display group number XXX
Indicated on display:
Note:
The display group number 1 is an example, to
illustrate the sequence.
- Select required display group number.
- Press buttons -0-, -0- and -1- for "Display group
number 1" and confirm entry with -Q- button.