Nissan Qashqai J11. Manual — part 522
EC9-244
< DTC/CIRCUIT DIAGNOSIS >
[R9M]
P0487 EGR VOLUME CONTROL VALVE
P0487 EGR VOLUME CONTROL VALVE
DTC Logic
INFOID:0000000010309178
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 1 minute before conducting the next test.
>> GO TO 2.
2.
PERFORM DTC CONFIRMATION PROCEDURE
1.
Turn ignition switch ON and wait at least 1 second.
2.
Check DTC.
Is DTC detected?
YES
>> Proceed to
EC9-244, "Diagnosis Procedure"
.
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000010309179
1.
CHECK HIGH PRESSURE EGR VOLUME CONTROL VALVE
Visually check high pressure EGR volume control valve for chipping.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace error-detected parts.
2.
CHECK ECM HARNESS CONNECTOR CONNECTIONS
Check ECM harness connector connection.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace error-detected parts.
3.
CHECK HIGH PRESSURE EGR VOLUME CONTROL VALVE HARNESS CONNECTOR CONNECTIONS
Check high pressure EGR volume control valve harness connector connection.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace error-detected parts.
4.
CHECK HIGH PRESSURE EGR VOLUME CONTROL VALVE CIRCUIT FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Check high pressure EGR volume control valve circuit for open and short.
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detecting condition
Possible cause
P0487
EGR VLV CMD CIRC
(Exhaust gas recirculation throt-
tle control circuit “A”/open)
• 1.DEF: OFFSET IMPLAUSI-
BLE
ECM detects abnormally closed posi-
tion of high pressure EGR volume con-
trol valve.
• Harness or connectors
• High pressure EGR volume control
valve
• High pressure EGR valve position sen-
sor
P0487 EGR VOLUME CONTROL VALVE
EC9-245
< DTC/CIRCUIT DIAGNOSIS >
[R9M]
C
D
E
F
G
H
I
J
K
L
M
A
EC9
N
P
O
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Repair or replace error-detected parts.
5.
DTC CONFIRMATION PROCEDURE
1.
Erase DTC.
2.
Perform DTC confirmation procedure again. Refer to
.
Is the DTC P0487 displayed again?
YES
>> GO TO 6.
NO
>> Check intermittent incident. Refer to
GI-41, "Intermittent Incident"
.
6.
CHECK HIGH PRESSURE EGR VOLUME CONTROL VALVE MOTOR
EC9-245, "Component Inspection (High Pressure EGR Volume Control Valve Motor)"
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-41, "Intermittent Incident"
.
NO
>> Replace error-detected parts.
Component Inspection (High Pressure EGR Volume Control Valve Motor)
INFOID:0000000010309180
1.
CHECK HIGH PRESSURE EGR VOLUME CONTROL VALVE MOTOR
1.
Turn ignition switch OFF.
2.
Disconnect high pressure EGR volume control valve harness connector.
3.
Check resistance between high pressure EGR volume control valve terminals as follows.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace high pressure EGR volume control valve.
+
-
Continuity
ECM
High pressure EGR volume
control valve
Connector
Terminal
Connector
Terminal
F83
106
F14
6
Existed
108
4
110
5
144
1
148
2
High pressure EGR volume control
valve
Resistance (Approx.)
+
-
Terminal
1
2
2.35
Ω
EC9-246
< DTC/CIRCUIT DIAGNOSIS >
[R9M]
P0488 EGR SYSTEM
P0488 EGR SYSTEM
DTC Logic
INFOID:0000000010309181
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 1 minute before conducting the next test.
>> GO TO 2.
2.
PERFORM DTC CONFIRMATION PROCEDURE
1.
Turn ignition switch ON and wait at least 3 seconds.
2.
Check DTC.
Is DTC detected?
YES
>> Proceed to
EC9-246, "Diagnosis Procedure"
.
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000010502829
1.
CHECK HIGH PRESSURE EGR VOLUME CONTROL VALVE
Visually check high pressure EGR volume control valve for chipping.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace error-detected parts.
2.
CHECK ECM HARNESS CONNECTOR CONNECTIONS
Check ECM harness connector connection.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace error-detected parts.
3.
CHECK HIGH PRESSURE EGR VOLUME CONTROL VALVE HARNESS CONNECTOR CONNECTIONS
Check high pressure EGR volume control valve harness connector connection.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace error-detected parts.
4.
CHECK HIGH PRESSURE EGR VOLUME CONTROL VALVE CIRCUIT FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Check high pressure EGR volume control valve circuit for open and short.
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detecting condition
Possible cause
P0488
EGR VALVE POSITION CN-
TRL
(Exhaust gas recirculation
throttle control circuit “A”
range/performance)
• 1.DEF: NO RESPONSE
FROM THE VALVE MO-
TOR
• 2.DEF: VALVE LOCKED
ECM detects high pressure EGR volume
control valve regulation error.
• Harness or connectors
• High pressure EGR volume control valve
• High pressure EGR volume control valve
position sensor
P0488 EGR SYSTEM
EC9-247
< DTC/CIRCUIT DIAGNOSIS >
[R9M]
C
D
E
F
G
H
I
J
K
L
M
A
EC9
N
P
O
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Repair or replace error-detected parts.
5.
DTC CONFIRMATION PROCEDURE
1.
Erase DTC.
2.
Perform DTC confirmation procedure again. Refer to
.
Is the DTC P0488 displayed again?
YES
>> GO TO 6.
NO
>> Check intermittent incident. Refer to
GI-41, "Intermittent Incident"
.
6.
CHECK HIGH PRESSURE EGR VOLUME CONTROL VALVE MOTOR
EC9-247, "Component Inspection (High Pressure EGR Volume Control Valve Motor)"
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-41, "Intermittent Incident"
.
NO
>> Replace error-detected parts.
Component Inspection (High Pressure EGR Volume Control Valve Motor)
INFOID:0000000010309183
1.
CHECK HIGH PRESSURE EGR VOLUME CONTROL VALVE MOTOR
1.
Turn ignition switch OFF.
2.
Disconnect high pressure EGR volume control valve harness connector.
3.
Check resistance between high pressure EGR volume control valve terminals as follows.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace high pressure EGR volume control valve.
+
-
Continuity
ECM
High pressure EGR volume
control valve
Connector
Terminal
Connector
Terminal
F83
106
F14
6
Existed
108
4
110
5
144
1
148
2
High pressure EGR volume control
valve
Resistance (Approx.)
+
-
Terminal
1
2
2.35
Ω