Suzuki Grand Vitara JB416 / JB420. Manual — part 138
1J-10 Charging System:
Water Pump and Generator Drive Belt Removal
and Installation (For J20 Engine)
S5JB0A1A06014
Removal
WARNING
!
Disconnect negative (–) cable at battery
before removing and installing generator
belt.
1) Loosen tensioner by turning the tensioner pulley (2)
clockwise.
2) While holding the tensioner and belt loose, remove
generator belt (1).
Installation
1) Loosen tensioner by turning the tensioner pulley (2)
clockwise.
2) While holding the tensioner, install generator belt (1).
NOTE
• Make sure that the belt fits each pulley’s
groove properly.
• After installing generator belt, make sure
that tension indicator is within standard
range referring to “Water Pump and
Generator Drive Belt On-Vehicle Inspection
(For J20 Engine)”.
3. Tensioner pulley bolt
I3TR011A4001-01
3. Tensioner pulley bolt
I3TR011A4001-01
Charging System: 1J-11
Generator Dismounting and Remounting
S5JB0A1A06006
[A]
[B]
(a)
(b)
(c)
(b)
(c)
7
1
8
2
9
6
4
8
(a)
3
1
7
2
9
6
5
3
(c)
(c)
I5JB0A1A0003-02
[A]: For M16 Engine
4. Generator adjusting bolt (For M16 Engine)
9. Generator
[B]: For J20 Engine
5. Generator mounting bolt (For J20 Engine)
: 7.0 N
⋅m (0.7 kgf-m, 5.0 lb-ft)
1. “B” terminal wire
6. Generator pivot bolt
: 52.5 N
⋅m (5.25 kgf-m, 38.0 lb-ft)
2. coupler
7. “B” terminal nut
: 25 N
⋅m (2.5 kgf-m, 18.5 lb-ft)
3. Water pump and generator drive belt
8. Generator blacket bolt
1J-12 Charging System:
Dismounting
1) Disconnect negative (–) cable at battery.
2) Disconnect MAF sensor coupler (For J20 Engine).
3) Remove air cleaner case and air cleaner outlet hose (For J20 Engine).
4) Disconnect generator lead wire (“B” terminal wire) and coupler from generator.
5) Remove generator belt. Refer to “Water Pump and Generator Drive Belt Removal and Installation (For M16
Engine)” or “Water Pump and Generator Drive Belt Removal and Installation (For J20 Engine)”.
6) Remove generator drive belt adjusting bolt (For M16 Engine) and generator mounting bolt (For J20 Engine) and
generator pivot bolt.
7) Remove generator.
Remounting
1) Mount generator on the generator bracket.
2) Tighten generator mounting bolts and generator pivot bolt as specified torque (For J20 Engine).
3) Install generator belt. Refer to “Water Pump and Generator Drive Belt Removal and Installation (For M16 Engine)”
or “Water Pump and Generator Drive Belt Removal and Installation (For J20 Engine)”.
4) Connect “B” terminal wire and coupler to generator.
5) Install air cleaner case and air cleaner outlet hose (For J20 Engine).
6) Connect MAF sensor coupler (For J20 Engine).
7) Connect negative (–) cable at battery.
Generator Components
S5JB0A1A06007
12
11
13
14
(a)
(b)
(c)
(d)
1
2
3
4
5
6
7
8
9
10
15
16
I4RS0B1A0007-01
1. Pulley nut
6. Drive end bearing
11. Rear housing
16. “B” terminal nut
2. Pulley
7. Bearing retainer
12. Rectifier
: 118 N
⋅m (11.8 kgf-m, 85.5 lb-ft)
3. Front housing
8. Rotor
13. Regulator
: 4.5 N
⋅m (0.45 kgf-m, 3.5 lb-ft)
4. Stator
9. Rear end bearing
14. Brush
: 3.5 N
⋅m (0.35 kgf-m, 2.5 lb-ft)
5. Frame bolt
10. Retainer screw
15. “B” terminal
: 8.0 N
⋅m (0.8 kgf-m, 6.0 lb-ft)
Charging System: 1J-13
Generator Inspection
S5JB0A1A06009
Rotor
• Using ohmmeter, connect positive terminal to “FR” terminal and connect negative terminal to “B” terminal of
generator, check that continuity between “B” terminal and “FR” terminal. If there is no continuity, replace rotor or
regulator.
• Using ohmmeter, check for continuity between slip rings of rotor. If there is no continuity, replace rotor (1).
Resistance between slip rings of rotor
1.7 – 2.0
Ω
• Using ohmmeter, check that there is no continuity between slip ring and rotor core. If there is continuity, replace
rotor (1).
• Check slip rings for roughness or scoring. If rough or scored, replace rotor.
I5JB0A1A0012-01
IYSQ011A0035-01
IYSQ011A0036-01