Geely Emgrand X7. Manual part — 449
Geely Emgrand X7. Manual part - 449
2. Install upper and lower 2 hard pipe connector
of condenser and tighten it with bolt.
Notes:
The O-ring related in the process of installation must
be replaced by a new one.
3. Install the engine hood latch.
4. Install
horn.
5. Install
front
bumper.
6. A/C
refrigerant
filling
procedures
NL08-0049b
1795
8.3.8.16 A/C pipe replacement
Refrigerant A/C pipe replacement
Dismantle procedure
Warning!
See "Warnings for intake of R-134a" in 1.1.1.1 warning and precaution .
1. For operation of recycling procedures of A/C
refrigerant, refer to 8.2.7.12 recycling and filling
of A/C refrigerant.
2. Disconnect the battery negative cable. Refer to
2.11.8.1 battery cable disconnection/connection
Procedures.
3. For dismantling of fixing bolt of expansion valve
and removing of expansion valve, refer to 8.3.8.5
Replacement of expansion valve.
4. Dismantle front bumper, refer to 12.4.3.1
Replacement of Front Bumper.
NL08-0021b
5. Remove the A/C pipe rigid connector fixing bolt
on the expansion valve side.
6. Remove the fixing bolt for the A/C low pressure
pipe rigid connector on the compressor side.
NL08-0051b
7. Dismantle 2 brackets for the A/C low pressure
pipe from the evaporator to the compressor.
8. Dismantle the A/C low pressure pipe from the
evaporator to the compressor.
NL08-0052b
1796
9. Dismantle the lower A/C high pressure pipe rigid
connector on the condenser side.
NL08-0053b
10. For dismantling of A/C pressure switch, refer to
8.3.8.2 Replacement of A/C pressure switch.
11. Dismantle 2 supports from condenser to A/C
high pressure pipe of evaporator
12. Dismantle high pressure from condenser to
evaporator
NL08-0054b
13. Dismantle high-pressure pipe hard joint from
compressor side to condenser A/C.
NL08-0055b
1797
14. Dismantle A/C high-pressure pipe joint on the
top of condenser.
15. Dismantle A/C high-pressure pipe between
compressor and condenser.
NL08-0056b
Installation Procedure:
Notes:
The O-ring related in the process of installation must
be replaced by a new one. During installation of A/C
pipe, first insert thoroughly the pipe joint and then
tighten the bolt.
O-ring and pipeline joint are damaged.
1. Install A/C pipe and tighten A/C fixing bracket.
2. Tighten fixing bolt on expansion valve side.
NL08-0021b
3. Install high-pressure pipe hard joint bolt on the
upper section of condenser and tighten it.
NL08-0056b
1798
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.