Geely EC718, EC718RV, EC715, EC715RV. Manual part — 75
Geely EC718, EC718RV, EC715, EC715RV. Manual part - 75
FE02-0044b
3.
Connect the VVT solenoid valve wiring harness
connector.
Clean the solenoid valve filter:
FE02-0045b
1.
Remove the generator. Refer to
2.
Remove the VVT solenoid valve filter sealing bolts.
FE02-0046b
3.
Remove the VVT solenoid valve filter with a plier.
Engine
Control System JL4G18-D
2-215
FE02-0047b
4.
Clean the filter and make sure the solenoid valve is not
damaged or deformed, otherwise it must be replaced.
5.
Install the VVT solenoid valve filter.
FE02-0048b
6.
Install the solenoid valve filter and tighten the bolts.
Torque: 16.5 Nm (Metric) 12.2 lb-ft (US English)
7.
Install the generator.
8.
Connect the battery negative cable.
2.2.8.5 VVT Solenoid Valve Cleaning
Note
A. Inoperative near at high temperatures or near a fire
to avoid cleaning agents being ignited or exploded.
B. The length of wire should be more than 3m. It is
recommended to install the wire relay.
C. During the cleaning process, do not scratch the O-
ring, scratch or knock the surface of the valve or drop
the valve..
D. After repair, reinstall the valve VVT and tightening the
bolt to 10 Nm.
E. Replace repeatedly cleaned VVT valve.
2-216
Control System JL4G18-D
Engine
FE02-5139b
1.
Disconnect the battery negative cable. Refer to
.
2.
Remove VVT solenoid valve. Refer to
Solenoid Valve Replacement and Filter Cleaning
3.
Clean the VVT solenoid valve hole, return hole, the
chamber.
Note
During the cleaning process, keep the VVT solenoid
valve and wiring harness connector upright,
otherwise the cleaning agent will easily enter the
VVT solenoid valve and cause internal damage.
FE02-5140b
4.
Use an air gun to clean the VVT valve hole and oil
chamber. Clean up the cleaning agent residue.
FE02-5141b
5.
Switch on and off the VVT solenoid valve. Clean the valve
with an air gun and repeat 2-3 times.
Note
Each time switch the valve on no longer than the 2
s, otherwise the VVT solenoid valve may be
damaged.
Engine
Control System JL4G18-D
2-217
2.2.8.6 Engine Coolant Temperature Sensor
Replacement
Removal Procedure:
Warning!
Refer to "Cooling System Service Warning" in "Warnings
and Notices".
FE02-0049b
1.
Release cooling system pressure.
2.
Disconnect the battery negative cable. Refer to
.
3.
Disconnect the engine coolant temperature sensor wiring
harness connector.
4.
Remove the engine coolant temperature sensor.
Installation Procedure:
FE02-0050b
1.
Apply sealant on the engine coolant temperature sensor
thread.
2.
Install the engine coolant temperature sensor.
3.
Tighten the engine coolant temperature sensor.
Torque: 15 Nm (Metric) 11 lb-ft (US English)
4.
Connect engine coolant temperature sensor wiring
harness connector.
5.
Fill the engine coolant.
6.
Connect the battery negative cable.
2-218
Control System JL4G18-D
Engine