Geely EC718, EC718RV, EC715, EC715RV. Manual part — 346

Geely EC718, EC718RV, EC715, EC715RV. Manual part - 346

FE08-0021b

2.

Separate the radiator and the blower.

FE08-0022b

3.

Remove the evaporator upper air-conditioning short hard
pipe.

Heating, Ventilation and A/C System

Automatic Air-conditioning

8-55

FE08-0023b

4.

Remove the expansion valve retaining bolts and remove
the expansion valve.

Installation Procedure:

FE08-0024b

1.

Install the expansion valve and tighten the retaining bolts.

Torque: 18 Nm (Metric) 13.3 lb-ft (US English)

FE08-0025b

2.

Install the evaporator upper air-conditioning short hard
pipe.

Torque: 18 Nm (Metric) 13.3 lb-ft (US English)

3.

Assemble the radiator and the blower assembly.

4.

Install the air-conditioning assembly.

Note

During the installation, all the O-rings must be
replaced.

8-56

Automatic Air-conditioning

Heating, Ventilation and A/C System

8.2.8.7

Air-conditioning

Compressor

Replacement

Removal Procedure

Warning!

Refer to "Breathing R-134a Warning" in "Warnings and
Notices".

FE08-0064b

1.

Carry out the air-conditioning refrigerant recovery
procedure. Refer to

8.2.7.10

Air-conditioning Refrigerant

Recovery and Filling

.

2.

Disconnect the battery negative cable.Refer to

2.11.8.1

Battery Disconnection

.

3.

Remove the drive belt. Refer to

2.6.8.3

Drive Belt

Replacement

.

4.

Disconnect the compressor to air-conditioning high and
low pressure pipes.

1

2

2

2

FE08-0065b

5.

Disconnect the compressor harness connector (1).

6.

Remove the compressor retaining screws and remove the
compressor (2).

Note

To prevent impurities and moisture in air condensed
on the parts entering the system, seal all the parts
as soon as possible.

Heating, Ventilation and A/C System

Automatic Air-conditioning

8-57

Installation Procedure:

2

1

1

1

FE08-0066b

1.

Install and tighten the compressor retaining bolts (1).

Torque: 28 Nm (Metric) 20.7 lb-ft (US English)

2.

Connect the compressor harness connector (2).

FE08-0064b

3.

Install the compressor to air-conditioning high and low
pressure pipes.

Torque: 11 Nm (Metric) 8.1 lb-ft (US English)

4.

Install the driver belt.

5.

Connect the battery negative cable.

6.

Carry out the air-conditioning refrigerant filling procedure.

8.2.8.8 Blower Speed Control Module
Replacement

Removal Procedure

FE08-0026b

1.

Disconnect the battery negative cable. Refer to

2.11.8.1

Battery Disconnection

.

2.

Disconnect blower speed control module harness
connector.

3.

Remove the blower speed control module retaining
screws.

8-58

Automatic Air-conditioning

Heating, Ventilation and A/C System