Mitsubishi L200. Manual — part 193
TROUBLESHOOTING
DIESEL FUEL
13A-568
241 Differentia
l pressure
learning
temperatu
re (M7)
<Euro5>
Indicates the temperature when
the compensation amount (M7) of
exhaust differential pressure
sensor was saved.
Ignition switch: ON
35 to 44
°C
242 Differentia
l pressure
learning
zero (M7)
<Euro5>
Indicates the compensation
amount (M7) of exhaust differential
pressure sensor when the exhaust
differential pressure sensor
ambient air temperature is
between 35 and 44
°C.
Ignition switch: ON
−5.12 to 5.08
kPa
244 Differentia
l pressure
learning
temperatu
re (M8)
<Euro5>
Indicates the temperature when
the compensation amount (M8) of
exhaust differential pressure
sensor was saved.
Ignition switch: ON
45 to 54
°C
245 Differentia
l pressure
learning
zero (M8)
<Euro5>
Indicates the compensation
amount (M8) of exhaust differential
pressure sensor when the exhaust
differential pressure sensor
ambient air temperature is
between 45 and 54
°C.
Ignition switch: ON
−5.12 to 5.08
kPa
246 Differentia
l pressure
learning
temperatu
re (M9)
<Euro5>
Indicates the temperature when
the compensation amount (M9) of
exhaust differential pressure
sensor was saved.
Ignition switch: ON
55 to 64
°C
247 Differentia
l pressure
learning
zero (M9)
<Euro5>
Indicates the compensation
amount (M9) of exhaust differential
pressure sensor when the exhaust
differential pressure sensor
ambient air temperature is
between 55 and 64
°C.
Ignition switch: ON
−5.12 to 5.08
kPa
249 Differentia
l pressure
learning
temperatu
re (M10)
<Euro5>
Indicates the temperature when
the compensation amount (M10)
of exhaust differential pressure
sensor was saved.
Ignition switch: ON
65 to 74
°C
250 Differentia
l pressure
learning
zero
(M10)
<Euro5>
Indicates the compensation
amount (M10) of exhaust
differential pressure sensor when
the exhaust differential pressure
sensor ambient air temperature is
between 65 to 74
°C.
Ignition switch: ON
−5.12 to 5.08
kPa
Ite
m
No.
Inspectio
n item
Explanation of M.U.T. display
Guideline for inspection
Display range,
numerical
value
TROUBLESHOOTING
DIESEL FUEL
13A-569
251 Differentia
l pressure
learning
temperatu
re (M11)
<Euro5>
Indicates the temperature when
the compensation amount (M11) of
exhaust differential pressure
sensor was saved.
Ignition switch: ON
75 to 84
°C
252 Differentia
l pressure
learning
zero (M11)
<Euro5>
Indicates the compensation
amount (M11) of exhaust
differential pressure sensor when
the exhaust differential pressure
sensor ambient air temperature is
between 75 to 84
°C.
Ignition switch: ON
−5.12 to 5.08
kPa
254 Differentia
l pressure
learning
temperatu
re (M12)
<Euro5>
Indicates the temperature when
the compensation amount (M12)
of exhaust differential pressure
sensor was saved.
Ignition switch: ON
85 to 94
°C
255 Differentia
l pressure
learning
zero
(M12)
<Euro5>
Indicates the compensation
amount (M12) of exhaust
differential pressure sensor when
the exhaust differential pressure
sensor ambient air temperature is
between 85 and 94
°C.
Ignition switch: ON
−5.12 to 5.08
kPa
256 Differentia
l pressure
learning
temperatu
re (M13)
<Euro5>
Indicates the temperature when
the compensation amount (M13)
of exhaust differential pressure
sensor was saved.
Ignition switch: ON
95 to 104
°C
257 Differentia
l pressure
learning
zero
(M13)
<Euro5>
Indicates the compensation
amount (M13) of exhaust
differential pressure sensor when
the exhaust differential pressure
sensor ambient air temperature is
between 95 and 104
°C.
Ignition switch: ON
−5.12 to 5.08
kPa
259 Differentia
l pressure
learning
temperatu
re (M14)
<Euro5>
Indicates the temperature when
the compensation amount (M14)
of exhaust differential pressure
sensor was saved.
Ignition switch: ON
105 to 114
°C
260 Differentia
l pressure
learning
zero
(M14)
<Euro5>
Indicates the compensation
amount (M14) of exhaust
differential pressure sensor when
the exhaust differential pressure
sensor ambient air temperature is
between 105 and 114
°C.
Ignition switch: ON
−5.12 to 5.08
kPa
Ite
m
No.
Inspectio
n item
Explanation of M.U.T. display
Guideline for inspection
Display range,
numerical
value
TROUBLESHOOTING
DIESEL FUEL
13A-570
261 Differentia
l pressure
learning
temperatu
re (M15)
<Euro5>
Indicates the temperature when
the compensation amount (M15)
of exhaust differential pressure
sensor was saved.
Ignition switch: ON
115 to 124
°C
262 Differentia
l pressure
learning
zero
(M15)
<Euro5>
Indicates the compensation
amount (M15) of exhaust
differential pressure sensor when
the exhaust differential pressure
sensor ambient air temperature is
between 115 and 124
°C.
Ignition switch: ON
−5.12 to 5.08
kPa
318 DPF
regenerati
on
remaining
time
<Euro5>
Indicating DPF regeneration
remaining time. If DPF
temperature is low, numerical
value is not reduced.
On DPF regeneration
Indicating DPF
regeneration
remaining time
321 DPF
regenerati
on
<Euro5>
Showing whether DPF
regeneration is being performed or
not.
Ignition switch: ON
ON (during
DPF
regeneration),
OFF (during
not DPF
regeneration)
328 DPF
regenerati
on request
<Euro5>
Showing whether engine-ECU
requires DPF regeneration or not.
Ignition switch: ON
ON (during
DPF
regeneration
request), OFF
(during not
DPF
regeneration
request)
377 Max value
of DPF
temperatu
re
<Euro5>
Indicating maximum temperature
of DPF regeneration stored in
engine-ECU
Ignition switch: ON
−400 to 2,150
°C
384 Odometer
at DPF
temperatu
re max
value
<Euro5>
Indicates the driving distance at
the maximum DPF temperature
saved to the engine-ECU.
Ignition switch: ON
0
− 1,999,999
km
391 Count of
Regenerat
ion
Request
<Euro5>
Indicates the DPF regeneration
request times saved to the engine-
ECU.
Ignition switch: ON
0
− 65,535
Ite
m
No.
Inspectio
n item
Explanation of M.U.T. display
Guideline for inspection
Display range,
numerical
value
TROUBLESHOOTING
DIESEL FUEL
13A-571
404 Battery
current
sensor
(learning
value)
<Euro5>
Indicates the learning value of
battery current sensor calibration.
Ignition switch: ON
−6 to 6 A
435 Last
battery
deteriorat
ed
odometer
<Euro5>
Indicates the travel distance when
the battery is judged to be low at
the last time.
Ignition switch: ON
0
− 262,140 km
436 2nd last
battery
deteriorat
ed
odometer
<Euro5>
Indicates the travel distance when
the battery was judged to be low
two times before.
Ignition switch: ON
0
− 262,140 km
437 3rd last
battery
deteriorat
ed
odometer
<Euro5>
Indicates the travel distance when
the battery was judged to be low
three times before.
Ignition switch: ON
0
− 262,140 km
452 Battery
current
sensor
(learning
value of
neutral
point)
<Euro5>
• Indicates learning conditions of
battery current sensor
calibration.
• Message "Completed" means
learning has been completed.
Message "Not completed"
means learning has been not
completed.
Ignition switch: ON
Varies
depending on
the learning
conditions
454 Battery
degrade
judgement
flag
<Euro5>
Indicates the battery deterioration. Ignition switch: ON
ON
(deteriorated)
*2
, OFF (not
deteriorated)
455 Battery
full-charge
mode flag
<Euro5>
Indicates the battery full charge
control is being taken.
Ignition switch: ON
ON (the battery
full charge
control is being
taken.),
OFF (the
battery full
charge control
is not taken.)
Ite
m
No.
Inspectio
n item
Explanation of M.U.T. display
Guideline for inspection
Display range,
numerical
value