Volkswagen Golf / Golf GTI / Jetta. Manual — part 1036
01-56
- Using button -1-, the adaptation value can be
decreased as low as 120, using button -3
value can be increased as high as 136, e.g. 130.
Channel 30 Adaptation 130
Q
- 1 3-
- Indicated on display:
The fuel gauge is adapted correctly when the
needle rests on the center red demarcation
(reserve)!
When indication is OK:
- Press -Q- button to confirm input.
Channel 30 Adaptation 130
Q
Save modified value?
- Indicated on display:
- Press -Q- button to confirm input.
Channel 30 Adaptation 130
Modified value is saved
- Indicated on display:
- End adaptation of fuel gauge with
button.
Rapid data transfer
Help
Enter address word XX
Indicated on display:
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
01-57
Note:
Replace fuel gauge sender only if fuel gauge
cannot be matched correctly.
- Press buttons -0- and -6- to select function 06,
"End Output".
Rapid data transfer
Q
06 End Output
Indicated on display:
- Press -Q- button to confirm input.
Rapid data transfer
Help
Enter address word XX
Indicated on display:
The tester is now in basic function again.
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
01-58
Multi-function Indicator (MFI) fuel
consumption indicator, adaptation
Notes:
Consumption indicator can only be adapted
once between 85% and 115%.
Value must be entered in steps of 5%.
- Connect scan tool VAG 1551, select operating
mode 1 "Rapid data transfer", switch on ignition
and enter address word 17 "instrument cluster".
- Press -Q- button to confirm input.
- Press
button until "Select function"appears in
display.
Rapid data transfer
HELP
Select function XX
Indicated on display:
- Press buttons -1- and -0- to select "Adaptation"
function 10.
Rapid data transfer
Q
10 - Adaptation
Indicated on display:
- Press -Q- button to confirm input.
Adaptation
Enter channel number XX
Indicated on display:
- Press buttons -0- and -3- to select adaptation
"channel 03".
- Press -Q- button to confirm input.
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
01-59
Channel 03 Adaptation 100
- 1 3-
Indicated on display:
Note:
Correction of fuel consumption
display is only possible via direct
input.
- Press
button to continue.
Channel 03 Adaptation 100
Enter adaptation value XXXXX
Indicated on display:
Example:
Desired input value: 90% = button
pad entry: 00090
- Input desired correction value
using scan tool button pad, filling
initial positions with "0".
Channel 03 Adaptation 100
Q
Enter adaptation value 00090
Indicated on display:
- Press -Q- button to confirm input.
Channel 03 Adaptation 90
Q
- 1 3-
Indicated on display:
- Press -Q- button to confirm input.
Channel 03 Adaptation 90
Q
Store changed value?
Indicated on display:
- Press -Q- button to confirm input.
Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)
13/2/2005
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.