Volkswagen Golf / Golf GTI / Jetta. Manual — part 255
28-40
Misfire detection, checking
Special tools and equipment
Note:
All functions which could previously
be performed with VAG 1551/1552
can also be performed with the VAS
5051.
Test requirements
VAG 1551 Scan tool (or VAG
1552 Scan tool) with VAG 1551/3
adapter cable
The fuses must be OK.
The battery voltage must be at
least 11.5 V.
Engine mechanically OK.
No DTCs must be stored in DTC
memory
Page 01-23
.
Ignition system, servicing
28-41
Test sequence
- Test drive vehicle.
Observe the valid safety precautions when
performing a road test
Page 28-12
.
- Connect VAG 1551 Scan tool (or VAG 1552)
and select engine electronics control module
with "Address word" 01. Engine must be running
at idling speed: (Connecting scan tool and
selecting engine electronics control module
Page 01-12
).
Rapid data transfer
HELP
Select function XX
Indicated on display:
- Press buttons -0- and -8- for function "Read
measured value (data) block" and confirm entry
with -Q- button.
Read measured value block
Input display group number XXX
Indicated on display:
- Press buttons -0-, -1- and -4- for "Display group
number 14" and confirm entry with -Q- button.
Read measured value block 14
1
2
3
4
Indicated on display: (1 to 4
display zones)
Ignition system, servicing
28-42
- Check misfire detection status in display zone
4.
Specification: "activated"
- Check total number of misfires in display zone
3.
Specification: 0
If the specifications are obtained:
- Press
button.
- Press buttons -0- and -6- for function "End
output" and confirm entry with -Q- button.
- Switch off ignition.
If the specifications are not obtained:
- Change to display group 15 as follows:
- Press button 3 ((VAG 1551) or button (VAG
1552).
Read measured value block 15
1
2
3
4
Indicated on display: (1 to 4
display zones)
Ignition system, servicing
28-43
- Check misfire detection status in display zone
4.
Specification: "activated"
- Check display zones 1 to 3 for detected misfires
in cylinders cylinders 1 to 3.
Specification: 0
If the specifications are not obtained:
- Press
button.
- Press buttons -0- and -6- for function "End
output" and confirm entry with -Q- button.
- Switch off ignition.
Evaluating display group 15 and display group
16,
Page 01-207
.
If the specifications are obtained:
- Change to display group 16 as follows:
- Press button 3 ((VAG 1551) or button (VAG
1552).
Read measured value block 16
1
2
3
4
Indicated on display: (1 to 4
display zones)