Volkswagen Golf / Golf GTI / Jetta. Manual — part 220
24-134
Note:
The bits in display zone 1 will not be set to 1 until
the Three Way Catalytic Converter (TWC)
temperature rises above 380 C (
display
groups 34, display zone 2).
If the specification is not obtained:
- Press
button.
- Check Heated Oxygen Sensor (HO2S)
Page
24-38
.
If the specification is obtained:
- Change to display group 32 as follows:
- Press -C- button.
Read measured value block
Input display group number XXX
Indicated on display:
- Press buttons -0-, -3- and -2- for "Display group
number 32" and confirm entry with -Q- button.
Read measured value block 32
1
2
Indicated on display: (1 to 2
display zones)
- Check Oxygen Sensor learned values at idle
speed (additive) in display zone 1.
Specification: -5.4 to 5.4 %
Functions, checking
24-135
- Check Oxygen Sensor learned values at part
load (multiple active) in display zone 2.
Specification: -10.0 to 10.0%
If the specifications are not obtained:
- Press
button.
- Press buttons -0- and -6- for function "End
output" and confirm entry with -Q- button.
- Switch off ignition.
- Evaluate display group 32
Page 01-221
.
If the specifications are obtained:
- Change to display group 33 as follows:
VAG 1551: Press button -3-
VAG 1552: Press button
Read measured value block 33
1
2
Indicated on display: (1 to 2
display zones)
- Check Oxygen Sensor control in display zone 1.
Display must fluctuate in range of -10.0 to 10.0%
by at least 2%.
- Check Oxygen Sensor control in display zone 2.
Display must fluctuate in range of 1.400 to 1.600
V.
Functions, checking
24-136
If the displays in display zones 1 and 2 fluctuate:
- Press
button.
- Press buttons -0- and -6- for function "End
output" and confirm entry with -Q- button.
- Switch off ignition.
If one or both of the displays in zones 1 and 2
display a value constantly:
- Press
button.
- Press buttons -0- and -6- for function "End
output" and confirm entry with -Q- button.
- Switch off ignition.
- Check wiring of Heated Oxygen Sensor (HO2S)
Page 24-138
.
If the Oxygen Sensor control in display zone 1
does not fluctuate in the stated range:
- Press
button.
- Press buttons -0- and -6- for function "End
output" and confirm entry with -Q- button.
Functions, checking
24-137
- Road test vehicle to remove possible
contaminates on Oxygen Sensor (O2S) and
repeat check.
Observe the valid safety precautions when
performing a road test
Page 24-33
.
If the specifications in display zone 1 are not
obtained even after a road test, or the value does
not fluctuate by at least 2%:
- Check Heated Oxygen Sensor (HO2S) for aging
Page 24-150
.
Possible causes of Diagnostic Trouble Code
(DTC) when continuous regulation of sensor
is too slow:
The slots or holes in sensor body are blocked
The sensor breather hole in area of connecting
cable is blocked
The sensor has been overheated (glazed)
The sensor has been damaged by leaded
fuel
Functions, checking
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст